Cat6A & data-center Ethernet cable manufacturer

A Cat6A and Ethernet cable manufacturer for structured cabling and the data center — Cat6A (the enterprise default), Cat6, and Cat5e patch cords, keystone-terminated runs, and bulk cable on the spool. Shielded (F/UTP, S/FTP) or UTP, CMR or CMP jacket, wiremap-tested to TIA-568.

Ethernet / Cat cables

Build to your spec

HTS 8544.42.90
CategoryCat6A · Cat6 · Cat5e · shielded (F/UTP, S/FTP) or UTP
FormMolded patch cords, keystone runs, bulk on spool / box
CertificationUL AWM · CMR / CMP · TIA-568 · RoHS
Private labelLength, boot color, jacket rating, print legend; your carton
OriginVietnam or China — your election, documented per unit
Discuss your spec

Where ethernet / cat cables are used

How we build them

We mold, terminate, and test Cat6A, Cat6, and Cat5e — patch cords, keystone-terminated runs, and bulk cable on the spool or in the box. Every assembly is continuity- and wiremap-tested to TIA-568, in UTP or shielded (F/UTP, S/FTP) construction with CMR or CMP jacket ratings, your boot color, and your print legend for private-label programs.

Cat5e vs Cat6 vs Cat6A

CategoryBandwidthMax speed10G reachShielding
Cat5e100 MHz1 GbpsUTP
Cat6250 MHz1 Gbps (10G ≤ 55 m)55 mUTP or F/UTP
Cat6A500 MHz10 Gbps100 mF/UTP or S/FTP

The marks every build carries.

Product certifications on the label, the packaging, and the documentation your procurement team audits against — verifiable by file number on request.

cULus ListedcULus LISTED
cRUus RecognizedcRUus REC.
cETLus IntertekcETLus
CECE
FCC Part 15FCC PART 15
RoHSRoHS
REACHREACH

Manufacturing operates under  ISO 9001:2015 · ISO 14001:2015 ·ISO/IEC 27001:2022 · TL 9000-H · QC 080000 HSPM · ESD S20.20 ·Amfori BSCI

See how we source

Ethernet / Cat cables — common questions

Which Ethernet categories do you supply?

Cat5e, Cat6, and Cat6a — shielded (F/UTP, S/FTP) or unshielded (UTP) — as molded patch cords, keystone-terminated field runs, or bulk on the spool.

Are the patch cords TIA-568 compliant and jacket-rated?

Yes. Assemblies are tested to TIA-568 performance and carry UL AWM jacket ratings in CMR (riser) or CMP (plenum), plus RoHS.

What is the difference between CMR and CMP jackets, and which do I need?

CMR (riser) is for vertical runs between floors; CMP (plenum) is the higher fire rating required in air-handling spaces. Tell us the install environment and we jacket accordingly.

Can you do custom lengths, boot colors, and print legends?

Yes — length, boot color, jacket rating, and a custom cable-print legend (your text or part number) to spec.

Do you supply bulk cable as well as finished cords?

Yes — bulk Cat5e/6/6a on the spool or in a pull-box, alongside molded and field-terminated assemblies, with origin documented per unit.