A network switch with Ethernet cables connected.

Insights · Tool

Cat cable selector

Answer four questions — speed, distance, PoE, and where it runs — and get the right Ethernet category, shielding, and construction.

Specs from ANSI/TIA-568 & IEEE 802.3 · reviewed · the full Ethernet guide

The category printed on the box is a promise about speed, distance, and interference. Pick the one your run actually needs — under-spec and it will not certify; over-spec and you have paid for headroom you will never use. Answer four questions and this points to the right grade.

feet · ≈ 79 m

Recommended

Cat6a

10 Gigabit — Cat6a is the reliable 10G-to-100 m spec.

ShieldingF/UTP (foil)
ConductorSolid, 23 AWG
Bandwidth500 MHz
Reach10 GbE to 100 m
  • A clean office run can use UTP Cat6a, but it is bulkier — foil (F/UTP) is the safe default.
  • Bare copper only — copper-clad aluminum (CCA) will not certify and is a PoE and fire-code risk.
  • Match the jacket fire rating to the space: CM (general), CMR (riser), or CMP (plenum), per the NEC.
Source this cable →

The categories at a glance

CategoryMax speed & reachBandwidthTypical shielding
Cat5e1 GbE to 100 m100 MHzU/UTP
Cat610 GbE to ~55 m; 1 GbE to 100 m250 MHzU/UTP
Cat6a10 GbE to 100 m500 MHzF/UTP or U/FTP
Cat825/40 GbE to 30 m2000 MHzF/UTP or S/FTP

The reasoning behind each pick — the 10-Gigabit distance cutoff, why Cat7 is a marketing step, and the copper-vs-CCA problem — is in the full Ethernet guide. This selector is a sourcing starting point, not a substitute for a channel test on the installed link.

Sources

  • Twisted-pair cabling categories (Cat5e–Cat8)ANSI/TIA-568
  • Ethernet physical layers (1000/10G/25G/40GBASE-T, PoE)IEEE 802.3

Sourced to a real channel spec — in bare copper.

Kestner sources Cat5e through Cat6a patch and bulk cable to the category you actually need — bare copper, the right jacket rating, and cable verified to spec — from a US company that stands behind the paper.